Specifications:

Detection mode: Absorbance

Wavelength range: 190 nm - 900 nm, selectable in 1 nm increments

Light source: Tungsten halogen and deuterium

Detector: Linear CCD SONY 2048

Minimum sample size for Nano Mabna microplate: 1-2 µl

Minimum sample size for cuvette: 1 ml

Wavelength accuracy: 0.1 nm

OD accuracy: 0.002 OD

Spectral bandwidth: 1 nm

Dynamic range: 0 - 70 OD

Limit of detection: 2ng/μL (dsDNA)

Resolution: ± 0.01 OD

wavelength repeatability: ±0.2 nm

Power: 100 - 240 Volts AC. 50/60 Hz.

Software compatibility: Windows

Dimensions: 31 cm x 45 cm x 31 cm

Weight: 20 kg

The micro-volume spectrophotometer is a full-spectrum UV-VIS spectrophotometer in the range of 190-900 nm which is suitable for standard cuvettes and low volume samples measurements (1-2 μl). For highly concentrated samples it does not need any dilution. The micro-volume sample plate is not disposable and can be wiped and used again after a test which lowers the laboratory test expenses.

 

Some capabilities of this spectrophotometer are as follows:

- Performing bimolecular assays with low sample size

- Nucleic acid (RNA, DNA) and protein purity assessments and quantifications with low volume (1-2 μl)

- Quick absorbance measurements at 260 nm, 280 nm and 320 nm and also absorbance ratio of 260nm/280 and 260nm/230nm

- Full spectrum measurement in 190-900 nm wavelength range (1 nm increment)

- Kinetics measurement and graph display

- Concentration measurement, display calibration curve (standard curve) and regression number

- Storing unlimited data and recording of the full spectrum data every millisecond

- And etc.

Broad applications

Enzyme kinetics, Nucleic acid and protein quantification, Cell based tests such as cell growth studies Bacterial identification, Cell proliferation, Cytotoxicity, LSPR spectrometery, Reactive oxygen species, Food safety and quality, Total protein determination, Nucleic acid purity assessment. Biomolecular assays with low sample size eliminates dilution requirement for high concentrated analytes. Nucleic acid (RNA, DNA) and protein purity  assessments and quantifications can be done, using its special micro volume plate in which the low volume of the analyte as low as 2μl is only needed. This instrument enable the users to measure absorptions at 260, 280 and 230 nm and absorbance ratio of 260/280 and 260/230 for microvolume samples. The phases of bacteria growth can also be studied by OD measurement at 600 nm over time.

Quick measurement

Ultraviolet and visible (UV-Vis) absorption spectroscopy measurement can be done with a standard cuvette and also a  spesical micro volume plate designed for this instrument. Moreover, the full spectrum of analyte in wavelength range between 190 and 900 nm can be achieved in less than 1 ms. Optical density (OD) measurement at any wavelength in 1 nm increments at this range can also be made in less than 1 ms.

User-friendly software with QC analysis

The software guides the user step by step through testing procedures and helps user with error corrections warnings. In order to simplify data analysis, this software offers a full spectrum display and a table of data in Microsoft excel and txt format. Moreover, this instrument is capable of QC data collection and drawing of related graphs.

Advanced signal processing for higher accuracy

2048 ccd array detector provides a collection of large number of data for each sample. Advanced signal processing algorithm eliminates reading errors. Implementation of double beam algorithm compensates for light source fluctuations. By use of UV range data processing, the user can perform assays without any reagents for some parameters.

LSPR Nanosensing assays based on gold nanoparticles

Performing LSPR-based nano biosensing assays based on unique properties of gold nanoparticles, in different areas of industry and diagnostic immunity, genetics, and biochemistry are possible.

Endpoint, fixed time and kinetics analysis

A user can define a test and measure OD over the period of time. The measurement results are displayed in a graph. There is also a choice of three reading modes: Endpoint, fixed time and kinetics depending on user defined test.

Bacteria growth study

The phases of bacteria growth can be studied by OD measurement at 600 nm over time.

Cost effective

This instrument is a combination of three Laboratory Analytical Instruments:  microvolume spectrophotometer, UV-Vis spectrophotometer and LSPR instrument. Without losing the quality, the buyer pays for one instrument instead of paying three instruments. The micro-volume sample plate is not disposable and can be wiped and used again after a test which lowers the laboratory test expenses. 

Technical support

The instrument has a 2-year warranty and 10 years after-sales services for all customers. Our technical and scientific experts are always ready for technical supports.