Please Wait a Moment
X

Fully Automated Biochemistry & Chemistry Analyzer

 

 

Biochemistry & chemistry autoanalyzer  ABCNM99200

Specifications:

• Grating optical system with the ability to scan, plot the full spectrum and measure the absorption of light in wavelength range of 340 to 900 nm

• Benchtop configuration

• Dynamic range: 0-4OD

• Resolution: 0.005

• Reaction vessel temperature: 37 ± 0.3 with temperature fluctuations less than 0.1 degree

• Test method: End Point, Kinetic, Fixed time

• Possibility to perform tests with two reagents and two wavelengths

• Calibration methods: linear (single, double and multi-point)

• Quality control method: Westgard multi-rule, Cumulative sum check, Twin-plot

• 40 positions for sample and 40 positions for reagent  

• Accuracy of 0.5 microliter for reagent dispensing

• Accuracy 1 microliter for sample dispensing

• 200 tests per hour

• Dimensions (cm): 160 × 70 × 86

• Weight: 116 kg

• Power: 110-220 volts 50/60 Hz, 1000 watts

- Performing biochemical tests of blood serum and urine parameters in the field of healthcare

- Performing water chemical tests in industry

- High speed (maximum 200 tests per hour)

- Equipped with grating optical system with the ability to scan the whole wavelength range (340 to 900 nm)

- Performing the assays with bichromatic reading system (one for “sample” wavelength and the other one for “reference” wavelength)

- No dependence on a specific type of reagent

- Concentration measurement, calibration curve (standard curve) and regression number display

- Drawing of quality control curves

- Automatic process of mixing samples and reagents

- Equipped with a 37 degree incubator for heating reaction vessels

- Equipped with a refrigerator for long-term storage of reagents and samples

- Automatic sample and reagent suction and dispensing operation with an accuracy of 0.5 microliter

 

Broad applications

This device is used as a biochemical autoanalyzer in research centers, medical universities, medical diagnostic laboratories, hospitals and medical centers. Also, this device as a water autoanalyzer has the ability to measure chemical pollutants in water. This device is used in industries, reference laboratories, pharmaceutical, food, health, industries, power plants, water treatment industries (drinking, effluents, industrial water), agriculture, environment, universities, re.search centers. This device is suitable for optimizing new biochemistry and chemistry kits in real conditions and in a short time due to recording the full range of absorption spectra.oratories. It is suitable for optimizing the new biochemistry kit in real and .in a short time conditions due to recording the full range of absorption spectra

Measurable parameters

Performing biochemical and tubidity tests of blood, and etc., including: sugar, cholesterol, LDL, HDL, urea, uric acid, creatine, phosphorus, calcium, liver enzymes, etc.

Performing water parameters chemical tests: Sodium (Na), Potassium (K), Calcium (Ca), Magnesium (Mg), total hardness, total alkalinity, Iron (Fe), Chlorine (Cl), Sulphate (SO4), Nitrate (NO3), Nitrite ( NO2), Phosphate (PO4), Fluoride (F), Salt (NaCl), Heavy metals (Hg, Cd, Pb, As, ..), COD, TOC and E.coli bacteria and more.

Quick measurement

Visible absorption spectroscopy measurements are done using a standard cuvette. Moreover, the full spectrum of analyte in wavelength range between 340 and 900 nm can be achieved in less than 1 ms. Optical Absorbance measurement at any wavelength in 1 nm increments at this range can also be performed.

User-friendly software with QC analysis

The software guides the user step by step through testing procedures and helps user with error corrections warnings. In order to simplify data analysis, this software offers a full spectrum display and a table of data in Microsoft excel and txt format. Moreover, this instrument is capable of QC data collection and drawing of related graphs.

Advanced signal processing for higher accuracy

2048 ccd array detector provides a collection of large number of data for each sample. Advanced signal processing algorithm eliminates reading errors. Implementation of double beam algorithm compensates for light source fluctuations.

LSPR Nanosensing assays based on gold nanoparticles

Performing LSPR-based nano biosensing assays based on unique properties of gold nanoparticles, in different areas of industry and diagnostic immunity, genetics, and biochemistry are possible.

Endpoint, fixed time and kinetics analysis

A user can define a test and measure OD over the period of time. The measurement results are displayed in a graph. There is also a choice of three reading modes: Endpoint, fixed time and kinetics depending on user defined test.

Bacteria growth study

The phases of bacteria growth can be studied by OD measurement at 600 nm over time.

Technical support

The instrument has a 2-year warranty and 10 years after-sales services for all customers. Our technical and scientific experts are always ready for technical supports.